HIGHT RESOLUTION TEMP. CONTROL KCMD-84 (KCMD84) Products
Product Details
- Introduction:
- Service Life: Use the Digital Controller within the following temperature and humidity ranges:
Temperature: −10 to 55°C (with no icing or condensation), Humidity: 25% to 85%.
●The products is fully conpatible with pressure sensors, temperature sensors, displacement sensors and liquid-level sensors.
●Display Mode:Digital display: -1999~9999, decimal place optional through settings;lightness bargraph display(level beams): 0-100%
●Bar-Graph Display:This is a function of displaying Measured value (PV),PV is displayed in a span of from 0 to 100 %.
●Can be output an alarm when the deviation, process value, set point, or manipulated value reaches a specified value.
●With any model that supports communications, you can use communications , Modbus-RTU
●With any model that provides a transfer process value as a 4 to 20 mA or 1 to 5 V transfer output. - Input Sensor:
- ●Current input (analog input): 4 to 20 mA DC, 0 to 20 mA DC
●Temperature input: CU50(–50.0~150.0℃)/PT100(–199.9~600.0℃)/K(–30.0~1300℃)/E(–30.0~700.0℃)/J(–30.0~900.0℃)/T(–199.9~400.0℃)/S(–30~1600℃)/R(–30.0~1700.0℃)/WR25(–30.0~2300℃)/N(–30.0~1200.0℃)
-A single input: The input sensor type is fix by the factory .Input type cannot be select. eg.the instrument\'s input type is 4 to 20 mA - Alarm (ALM) function:
- ●Process high alarm
●Process low alarm - Alarms:
- ●1~4 Relay outputs
- Dimensions:
- h×w×d(Unit: mm) 160×80×85 152×76;
A:96×96×110 92×92;
D:72×72×110 68×68;
E:48×96×110 44×92;
F:96×48×110 92×44;
G:48×48×110 44×44;
R(din35): 88mm ×72mm ×59mm 。 - Transfer Output:
- (Optional features)With any model that provides a transfer process value as a 4 to 20 mA or 1 to 5 V transfer output.
- Communications:
- (Optional features)RS485/RS232 Modbus RTU Communications
Register Address | Code | Name | Manual | Setting range | Ex-Factory |
0 | AL-1 | Alarm 1 | please refer to ALP1 | Depending on sensor type | 500.0 |
1 | HY-1 | Alarm Differential gap | Alarm relay contact may repeat its turning ON and OFF due to input fluctuation if measured value (PV) is near the alarm set value. An alarm differential gap setting can prevent the relay contact from ON or OFF repetition. | 0.1~100.0 | 0.5 |
2 | AL-2 | Alarm 2 | please refer to ALP2 | Depending on sensor type | 300.0 |
3 | HY-2 | Alarm Differential gap | Alarm2 Differential gap | 0.1~100.0 | 0.5 |
4 | AL-3 | Alarm 3 | please refer to ALP3 | Depending on sensor type | 800.0 |
5 | HY-3 | Alarm Differential gap | Alarm3 Differential gap | 0.1~100.0 | 0.5 |
6 | AL-4 | Alarm 4 | please refer to ALP4 | Depending on sensor type | 100.0 |
7 | HY-4 | Alarm Differential gap | Alarm4 Differential gap | 0.1~100.0 | 0.5 |
8 | LOCK | Set data lock | LOCK=18,
Set data unlock LOCK≠18, Set data lock. |
0~250 | 18 |
9 | SC | PV Bias | The value set in the PV bias is added to the actual input value to correct the input value. | ±100.0 | 0.0 |
10 | DP | Decimal position | When thermocouple and thermal resistance input, the decimal point set up the range of 0~1; when current and voltage input ,the decimal point set up the range of 0~3. | 0~3 | 1 |
11 | P-SH | Range high | The control is displayed after Input range. | P-SL~9999 | 999.9 |
12 | P-SL | Range low | 0~P-SH | ||
13 | G-SH | Bar-Graph high | Light Bar-Graph Display high limit and lower limit. | G-SL~P-SH | 999.9 |
14 | G-SL | Bar-Graph low | P-SL~G-SH | ||
15 | PF | Digital Filter | This is a 1st-order lay filter by software prepared in order to reduce fluctuations of measured value (PV) by noise. | 0~99 | 20 |
16 | ALP1 | Alarm1 type | 0:
Alarm function OFF; 1: Process high alarm 2: Process low alarm |
0~2 | 1 |
17 | ALP2 | Alarm2 type | |||
18 | ALP3 | Alarm3 type | |||
19 | ALP4 | Alarm4 type | |||
20 | ADDR | Address | Communication address can be set from 0 to 255 | 0~255 | 1 |
21 | BAUD | Communication speed | 1200; 2400; 4800; 9600; | —— | 9600 |